Made Sistemi

REC96-T3

Thermorecorder with 2 temperature channel and printer and 2 digital inputs
 

The thermorecorders "REC96-T3" derive from the model "V.0" and has been planned and produced with the characteristic criteria of robustness that mark the REC96 thermorecorder line by adopting one original mechanical solution in order to lodge a 24 characters printer inside it and to obtain a compact unit proper to be fixed in the cabin of a truck or outside.

The temperature recorder was planned specifically for use in refrigerated cells of trucks, in accordance with the D.M. n°493 of the 25/09/95 and it was certified with the decree of homologation N°552138 dated 8 JULY 1997 like first accredited product made in Italy.

It meets EN12830 normative and is conform to:
EN13486, 37/2005, 852/2004, 93/43CEE e HACCP.

The device measures and records temperatures in the range between -59.5°C and +59.5°C on three distinguished channels by means of sensors PT100 with three conductors for without compromises measures.

Cyclically the temperatures are visualized on a alphanumeric display with 2 lines of 16 characters with a resolution of 0.5°C together to running Time and several messages of service informations.

Through keyboard menu, with the same display are visualized the stored temperature or are set the extreme of the printout or "Vehicle" (es. no. plate) and a 12 characters code operator printed on the ticket printout. All the menu that change the functional characteristich of the device are protected from password.

Standard recording interval is fixed to 15 minutes but it is programmabile to 1, 2, 5, 10, 20, 30, 60 min.

Data memory allows for both channels until 160 days or recording (also not following) with an interval of 15 min. after that the new data will cancel the first ones acquired .

Identity of the thermorecorder is stored in a not modifiable serial code of 8 characters.

The thermorecorder displays and prints in 5 European languages: English, German, French, Italian and Spanish.

Customer has two ulterior levels of identification, the "Vehicle" (es. n° Plate Vehicle) and the "Operator" with 12 characters that will be printed on each data printout.

The internal printer use a dot impat mechanism and a cellulosa paper roll with a diameter of 30 mm and 57 mm wide.

The control circuit of printer adopts a autodiagnostic system for the protection of the mechanism against efforts derived from jams of the paper and our system "ENERGY SAVING" with total power down of the printer section if not in service.

The MODE of print is predefinable in: "Last number of days", "Mission", "Delivery" or "Last ON" in TEXT or GRAPHIC format.

The function of "Delivery" allows the release one ticket where are printed the values of the running time, identified from an automatic progressive number and the consequent memorization of last 60 events. The complete list is printable or transferable to a PC.

By the keyboard is possible to program the alarm threshold thermostat from -59°C to +59°C in step of 1°C with the activation of a bell when the temperature exceeds the alarm threshold.


The autodiagnostic controls all the events of anomaly and breakdown with criteria of priorities therefore to signal with appropriate combinations the lighting of the led "FAULT" and "OPER." the degree of urgency of intervent from authorized personnel.

The thermorecorder has two serial RS232. One of them (wired) is on the rear side (version "C") or inside (version "E") to the thermorecorder and is dedicated to the connection to remote devices like GPS-GSM-GPRS module, satellite system and alarm repeaters for the real time control of the temperature and data download.

If the device is associated to a GSM-GPRS module is available a SMS menu to send messagges for "thermostat alarm", "Fault", "Record" to three different telephone numbers or for the connection to an appropriate Call Center for remote control and/or data download.

The second serial RS232, localized in front of the thermorecorder (connector), can be connected to a PC that with Store96 software allow the data download and their consultation (in text, graphic or istogram form) and storage.

The connection to a PC is indispensable to configure all the not metrologically important parameter with the appropriate software at the autorized dealers.

REC96-T3 in the version "C" is built in a inox box (standard ISO radio size), it has an asportable front panel in painted steel and it is of easy installation by the supplied accessories.

REC96-T3 in the version "E" is built in a polycarbonate box with trasparent panel and it's supplied of the accessories for easy installation outside the cabin of a truck.

Both the versions need no regolation before to first installation, by being calibrated yet in laboratory and with a compensation system of the lenght of the cables and of the variations of the temperature of working.

Thecnical characteristics
mod.
REC96-T3C
REC96-T3E
Supply
9 / 32 VDC
Current absorbed:
(not printing V=12,6): 30 mA
Average current:
(average printing V=12,6): 350 mA
" " (peak during printing):
0,8 A (V=12,6 - density 50 %))
Printing speed:
2 lps
Associable sensors:
3 (mod. PT100 with 3 wire)
Digital inputs:
2
EN12830 designation:
TB1 -59.5 + 59.5
Display LCD backlite:
16 x 2 characters
Recording interval:
1, 2, 5, 10, 15, 20, 30, 60 min.
Memory:
32000 x 2 byte
Field of measure:
-59.5 / +59.5 °C
Resolution:
0.1 °C
Displaied and stored division:
0.5 °C
Precision (from -30 to + 30 °C):
± 0.5 °C
Accuracy class:
1
Alarm thermostat threshold:
-59 / +59 °C
Thermostat alarm activation delay:
0/6000 sec.
Clock precision:
< 0.004 %
Field of use:
- 40 / + 80 °C
Enclusure degree protection:
20 IP
65 IP
Sensor degree protection:
68 IP
Dimensions:
186 x 160 x 56 mm
213 x 185 x 117 mm

 

N.B.: characteristics measured in combination with SON96V.0 sensor