Made Sistemi

REC96-TGU

Recorder with one temperatur, humidity, Co2 channel and 2 digital inputs and printer
 

The normative (CE) N. 1/2005 of 22 december 2004 has highlighted the need to transport live animals within parameters that can ensure a degree of wellness. It then checks the temperature and the air qualilty degree where, we believe, the humidity and the CO2 can be an important factor.

The recorder ensures that the transport took place by these conditions, as well as to alert the driver to intervent to prevent unnecessary suffering or die-offs.

Furthermore, in the specific transport of chicks, the control and recording of the carbon dioxide level are essential for the purpose of reducing the mortality rate during and after the journey with the certification of the health status of the product upon delivery.

The thermo-hygrorecorders "R-20083U" has been planned to answer to these needs and it meets EN12830 normative and is conform to EN13486, 37/2005, 852/2004, 93/43CEE e HACCP.

The device measures and records temperature, humidity, CO2 and the status of digital inputs (es: doors or ramp)

Standard recording interval is fixed to 15 minutes but it is programmabile to 1, 2, 5, 10, 20, 30, 60 min.

Data memory allows for both channels until 160 days or recording (also not following) with an interval of 15 min. after that the new data will cancel the first ones acquired.

Identity of the recorder is stored in a not modifiable serial code of 8 characters an ulterior level of identification called "personal code" (es. n° Plate Vehicle) by 12 characters that will be printed on each data printout. At last it is possible to add an intestation on the top ot the print report with 12 or 16 characters.

The recorder displays and prints in 5 European languages: English, German, French, Italian and Spanish. Like required in some European Countries for international transport, it was implemented the "language of printing" (between the five availables). So it will be possible to get a printout by a different language from each destination. It can be saved and used for a direct printing.

The internal printer use a dot impact mechanism and a cellulosa paper roll with a diameter of 30 mm and 57 mm wide.

The control circuit of printer adopts a autodiagnostic system for the protection of the mechanism against efforts derived from jams of the paper and our system "ENERGY SAVING" with total power down of the printer section if not in service.

REC96-TGU, in addition to the types of printing by mission, period or since last ON, has the "Delivery" function which allows the storage and release of receipts with the environmental data relating to the individual movements identified by an automatic progressive number, printable locally or transferable to a PC.

The verification of the presence of alarms or anomalies in the parameters is continuous according to priority criteria (PAM) that can be defined by the user in order to activate the internal acoustic signal, the alarm digital outputs and / or send any urgent intervention requests to a remote location . In a protected memory sector (AUDIT) the latest faults are recorded with the relative time references and the user operations that contribute to the evaluation of the quality of the data contained in the log. (in compliance with the indications of the WELMEC 7.2 directive for "P" type measuring instruments).

 


The thermo-hygrorecorder has two serial RS232. One of them (wired) is on the rear side (version "C") or inside (version "E") to the recorder and is dedicated to the connection to remote devices like GPS-GSM-GPRS module, satellite system and alarm repeaters for the real time control of the temperature and data download.

The second serial RS232, localized in front of the recorder (connector), can be connected to a PC that with Store96 software allows the data download and their consultation ( in text, graphic or istogram form) and storage.

If the device is associated to a GSM-GPRS module is available a SMS menu to send messagges for "thermo-humidistat alarm", "Fault", "Record" to three different telephone numbers or for the connection to an appropriate Call Center for remote control and/or data download.

The connection to a PC is indispensable to configure all the not metrologically important parameter with the appropriate software at the autorized dealers.

REC96 TGU in the version "C" is built in a inox box (standard ISO radio size), it has an asportable front panel in painted steel and it is of easy installation by the supplied accessories.

REC96 TGU in the version "E" is built in a polycarbonate box with trasparent panel and it's supplied of the accessories for easy installation outside the cabin of a truck.

Both the versions need no regolation before to first installation, by being calibrated yet in laboratory and with a compensation system of the lenght of the cables and of the variations of the temperature of working.

 

Thecnical characteristics
mod.
REC96 TGU C (internal)
REC96 TGU C (external)
Supply
10 / 31 VDC
Absorbed current
(not in printing a V=12,6): 40 mA
Corrente assorbita
(average in printing V=12,6): 350 mA
" " (peak during printing) :
0,8 A ( a V=12,6 - Density 50 %)
Printing speed:
2 lps
Temperature sensors:
2 (mod. PT100 a 3 fili)
Humidity sensors:
1 (mod.CO2MADE 0/5000ppm)
CO2 sensors:
1 (mod.CO2MADE 0/5000ppm)
Display LCD backlite:
12 x 3 characters
Recording interval :
1, 2, 5, 10, 15, 20, 30, 60 min.
Memory :
32000 x 2 byte
Temparature range of measure :
-59.5 / +59.5 °C
Temperature resolution :
0.1 °C
Displaied and stored division:
0.5 °C
Temperature precision :
± 0.5 °C (da -30 a + 30 °C)
Humidity range of measure :
5 / +99.5 %UR
Humidity resolution :
0,1 %UR
Displaied and stored division:
0,5 %UR
Humidity precision :
±5% (da 5 a 90 %UR)
CO2 range of measure:
0/4995 ppm
CO2 resolution :
25 ppm
CO2 displaied and stored division:
25ppm
CO2 precision :
+/- 100 ppm
Class :
1
Alarm thermostat threshold :
-59 / +59 °C
Alarm humidistat threshold :
0 / 99 %
Alarm CO2 threshold :
50/ 4950 ppm
Thermostat alarm activation delay:
0/600 sec.
Digital inputs
2 (optoisolated)
Digital output :
2 (open collector) alarm + fault
Clock precision :
< 0.004 %
Range of use :
- 40 / + 80 °C
Enclusure degree protection :
40 IP
65 IP
Temperature sensor degree protection :
68 IP (SON96)
Humidity sensor degree protection :
30 IP (HU-HPCF)
CO2 sensor degree protection :
30 IP (CO2MADE)
Dimensione:
186 x 160 x 56 mm
213 x 185 x 117 mm

 

N.B.: characteristics measured in combination with SON96V.0 and HU-HPCF-10 sensors CO2MADE